Study of Phase Transformation in Martensitic Stainless Steel AISI 422 During Continuous Cooling

Document Type : Research Paper

Authors

Abstract

In this research the behavior of the steel AISI 422 has been investigated during the various continuous cycle of cooling in dilatometer and CCT diagram has been obtained. The standard test samples were prepared in accordance with the requirements of the standard Dilatometers SEP 1681 in cylinders with a diameter of 4 mm and length of 10 mm. In the dilatometer test, heating the samples were conducted in controlled vacuum atmosphere. The results showed that after reaching the austenitizing temperature of 1040°C, holding time of 15 minutes , cooling time of 5, 15, 30 minutes, 1, 3, 6, 12 and 18 hours, martensite was formed in range of 238-300 °C. Colling In 24, 36 and 48 hours, pearlite phase was formed. The start temperature range of this transformation was 472-621°C and the final temperature rang of perlite transformation was 367-504°C. The martensite transformation for this cooling times was 300-310°C. In the cooling time of 36 hours, the bainite phase was formed in the temperature rang of 402-451°C. The results of this steel's hardenability test showed high hardenability and the jominy curve showed constant line

Keywords


 1- O. Ridge,"Elevated-Temperature Ferritic and Martensitic Steels and Their Aplication to Future Nuclear Reactors",U.S.Department of Energy,PP.10-19, November 2004.
2-F.B. Pickering,"Physical Metallorgy of Stainless Steel Developments ",Int.Met.Rev.211, PP.228-241, 1976.
3- JASM Handbook.,"Material Selection",9th Edition,Metals Handbook,ASM International, vol. 11, 1984.
4- P.M. Unterweiser, H.E. Boyer, and J.J. Kubbs,"Heat Treaters Guide Standard
Practices and Procedures for Steel",American Society for Metals,Metals Park,Ohio,4473.
5- C.F. Alvarez, C. Garcia, and V. Lopez,"Continuous Cooling Transformation in Martensitic Stainless Steels",ISIJ International,Vol. 34, No. 6,PP.516-521, 1994.
6- A. Garcia Junceeda, C. Capdevila, F.G. Caballero, and C. Garcia de Andres,"Dependence of Martensitic Start Temperaturs on Fine Austenite Grain Size ",ScriptaMateriale, Vol. 58,PP.134-137, 2008.
7- M. Atkins,"Atlas of Continuous Cooling Transformation Diagrams for Engineering Steels " British Steel Corporation, Shoffield, UK, PP.170-173,1985.
8- A. Garcia, F.G. Caballero, and L.F. Capdevila Alvarez, "Application of Dilatometry Analysis to the Study of Solid-Solid Phase Transformation in Steel", Materials Charactrization, Vol. 48, PP.101-111, 2002.
9- K. Amini, S. Nategh, and A. Shafee, "Influence of Different Cryotreatment on Tribological behavior of 80Crmo12-5 Cold Work Tool Steel", Material & Design, Vol. 31, No.12, PP.4666-4675, 2010.
10- M.C. Tsai, C.S. Chiou, and J.R. Yang, "PhaseTransformation in AISI 410 Stainless Steel ", Material Science and Engineering, Vol. 332, PP. 1